Print this page

Mantel-Widerstandstemperatursensoren

 

Mineral insulated (MI) Resistance Sensors (RTD – Resistance Temperature Detector)


Boylon offers MI Resistance sensor (RTD) with extension cables and/or with connection heads.

Outside diameter:
2 - 8 mm

Measuring range:

-50 + 600 °C
  3 wires or 4 wire system
Sensor element:
thin film element

 

Working Principle, explained as example for a Pt100:
A Pt100 temperature sensor is a resistance sensor (Resistance Temperature Detector, RTD) made of platinum. It has a typical resistance of 100 Ω at 0°C. If the Pt100 is connected to power, a voltage arises. By measuring this voltage, the resistance and following the temperature can be measured. The resistance of a Pt100 changes almost linearly with the temperature, Pt100 can usually measure temperatures up to 850°C.
.

Features - compared to thermocouples:
• higher accuracy
• strong and sensitive signal
• better stability

 

Class

Temperature
 Range [°C]

Type

Resistance R0 /Ω
in 0°C

Deviatin
 based on IEC 751

A2

-200°C ~
+850°C3

Pt10
Pt100

10Ω
100Ω

±(0,15+0,002∣t∣1)

B

Pt10
Pt100

10Ω
100Ω

±(0,30+0,005∣t∣1)

1 ∣t∣ is the absolute value of temperature in degree Celsius
2 Class A does for Pt element only with 3 or 4 wire system
3 Class A does not suit for Pt100 when T > 650 °C



Type

Resistance R0 /Ω at 0 ℃

W100 (R100 / R0)

 

Nominal

Deviation
based on IEC 751

Nominal

Deviation
based on IEC 751

Pt10

10Ω

Class A ±0,006
Class B ±0,012

1,3851

Class A ±0,0006
 Class B ±0,0012

Pt100

100Ω

Class A ±0,06
Class B ±0,12

1,3851

R100 s the resistance value when Pt element in 100 °C
R0 is the resistance value when Pt element in 0 °C
W100 Ratio R100 / R0






Examples:




 
  When you order please specify:

   L1 probe length:
 

   D probe diameter:

 

   Sheath material:

 

   L2 extension cable length:
 

   3 or 4 wires System:
 

   Insulation material of extension cable: