Boylon offers standard design MI thermocouples and Multipoint MI thermocouples.
Type: |
K, N, E, J, T, S, R |
|
Standard und Mehrfach |
|
simplex 2-adrig, duplex 4-adrig und triplex 6-adrig |
Material of sheath: |
SS304 (1.4301), SS321 (1.4541), SS316 (1.4401), SS310 (1.4841) und INCONEL 600 (2.4816) |
Diameter: |
∅ 0,5 mm - 8,0 mm |
Number of points: |
3 - 24 |
Probing length: |
max. 1600 mm |
Permitted deviations for thermocouples based on IEC 60584-2:
class |
Type |
Deviation |
Temp range [°C] |
|
I |
K |
±1,5 °C or |
-40 |
+1000 °C |
N |
-40 |
+1000 °C | ||
E |
-40 |
+800 °C | ||
J |
-40 |
+750 °C | ||
T |
±0,5 °C or |
-40 |
+350 °C | |
II |
K |
±2,5 °C or |
-40 |
+1200 °C |
N |
-40 |
+1200 °C | ||
E |
-40 |
+900 °C | ||
J |
-40 |
+750 °C | ||
T |
±1,0 °C or |
-40 |
+400 °C | |
III |
K |
±2,5 °C or |
-200 |
+40 °C |
N |
-200 |
+40 °C | ||
E |
-200 |
+40 °C | ||
J |
-200 |
+40 °C | ||
T |
±1,0 °C or |
+40 °C |
Example of multipoint MI thermocouple:
Please specify when ordering: |
|
Types: |
|
Class: |
|
Length of probe: |
|
Length of cable: |
|
Cable insulation material: |
|
Material of sheath: |
|
Diameter of probe: |
|
Measuring tip: |
|
Number of points: |
|
Distance of points: |
|